When using a, please first through cooling water, with low into the principle of higher, adjust the position of the pipe, guarantee cooling water full of cooling pipe, tube can't entities bubbles, and open power supply. Requirement: the soft water cooling water (distilled water or pure water), and often pay attention to the temperature of cooling water, water is warm should control in 25 ℃-30 ℃ scope, not too high or low, especially in summer, once found high water temperature, should change in time cooling water or stop to rest for a period of time: cold areas shall not be icy cooling water, especially laser after downtime, and shall not let cooling water reservoir in laser tube, lest cause cooling water ice crack. (note: the using ac cooling water tank, the user must grounding);


Second, laser tube of two supporting points in laser tube to a quarter of the total point, ensure the flow of cooling water in the 2 L-4 L/minutes; Otherwise the result is bad, can cause jump mode, flare change several points lead to power down; Cooling water back in tank (must be covered under water, or every time off boot laser tube with cooling water irrigation phenomenon.


Third, pay attention to the protection of the laser output window, avoid work process (including debugging light path process) produce smoke sputtering to output window surface, prevent output window outside surface is pollution, power will fall, when available ChouBu without water absorbent cotton or dip in alcohol wipe gently output window outside surface;


Four, in the commissioning process, by adjusting the laser strong point or rotating laser position, in order to achieve the best output effect, again will laser fixed.


Five, please be sure to note: avoid high voltage electrode piles up near the dust, keep dry, the high pressure as much as possible from the point of the metal, in case the high voltage spark discharge.


Six, laser in use process, can not have the scale in cooling tube form, so as to avoid the cooling water plugging, come loose hot effect becomes poor. Once found, can use 20% of the rare hydrochloric acid cleaning cooling tube, remove scale.


Seven, laser for glass products, fragile. Installation use, avoiding local stress.


Eight, reasonable application of laser tube, save the laser energy, laser tube work current optimal point in 16 ma.


CO2 laser tube common trouble shooting


A, must not wear:


1, a luminous cuts don't wear: first check of laser tube bearing point whether reasonable, strong light set whether is too small, light path is offset, focal length is correct, whether on the surface of yb have Nick and dirt, cooling water traffic flow pressure is normal, above a few no problem just check out of laser tube is light in the mouth lens whether have Nick and dirty content, if also normal word then is the quality problem of laser tube itself.......


2, the emitting a moment to must not wear: this question to check the laser tube bearing point whether reasonable, whether water temperature more than 30 degrees, lens at work, whether fever, cooling water traffic flow pressure is not normal, cooling water is clean, the above normal and then check of laser tube


Second, high voltage spark and discharge: check the high pressure head have around dirt and wet, from metal parts of the machine is too near; The other is laser power supply device from high-voltage connection is off the pedestal, high-voltage connection device if internal and destroy the bolt. If above normal word then is the quality problem of laser tube itself.......


Three, laser tube cracked, old, and water head fall off:


1. Whether in 25 ℃ temperature control-30 ℃ scope, cold areas shall not be icy cooling water, especially laser after downtime, and shall not let cooling water reservoir in laser tube.


2. Whether water protection in light under the control of the work; (test will shine as water hige and shine or light)


3. Water pipes have can play the open phenomenon.


4. Laser tube will exist if bubbles.


5. The water pressure is normal; The direction of flow is low higher into.